Difference between revisions of "Benchmarking: Specific Energy Consumption Models"

From SAGMILLING.COM
Jump to: navigation, search
(Benchmarking: Bond/Barratt SAB Circuit Specific Energy Consumption - Selbaie)
(Benchmarking: Bond/Barratt SAB Circuit Specific Energy Consumption - Selbaie)
Line 360: Line 360:
 
''Wood, K. and Duval, L.'', '''Mill Expansion at Les Mines Selbaie''', Proceedings of the 25th Anniversary Issue of the Canadian Mineral Processors, Ottawa, Canada (Paper № 8), January 1987.
 
''Wood, K. and Duval, L.'', '''Mill Expansion at Les Mines Selbaie''', Proceedings of the 25th Anniversary Issue of the Canadian Mineral Processors, Ottawa, Canada (Paper № 8), January 1987.
   
  +
* SAB circuit
  +
* SAG feed F<sub>80</sub> = 117 mm
  +
* cyclone overflow, P<sub>80</sub> = 45 &micro;m
   
 
{|class="wikitable" border="1"
 
{|class="wikitable" border="1"

Revision as of 01:46, 29 December 2016

Benchmarking: Amelunxen SGI - Agnico Eagle Laronde

Starkey, J., Robitaille, J., Cousin, P., Jordan, J. and Kosick, G., Design of the Agnico-Eagle Laronde Division SAG mill. Proceedings of SAG 2001, pages III-165 to III-178.

  • Survey conducted for six months after start-up
  • Specific energy values corrected to "mill shell" basis (motor input basis given in the reference)

Result for default Amelunxen SGI SAB model conditions:

Esag Epeb Ebm Etotal t/h
Predicted 6.5 - 6.9 13.4 196
Survey 6.1 - 6.4 12.5 210
Difference 0.4 - 0.5 0.9 14
Difference model 7% high - model 8% high model 7% high model 7% low

Show details of benchmarking

Benchmarking: Bond/Barratt - Cadia East (underground)

Engelhardt, D., Robertson, J., Lane, G., Powwel, M.S. and Griffin, P., Cadia Expansion - From open pit to block cave and beyond. Proceedings of MetSoc 2012.

  • Design criteria and plant trial of underground Cadia East ore
  • Ore was blasted underground and had F80 = 80 mm on surface

Result for default Optimized Bond/Barratt SABC model conditions:

ESAG Eball Etotal t/h
Model 12.2 kWh/t 15.1 kWh/t 27.7 kWh/t 1294 t/h
Measured 10.6 kWh/t 13.2 kWh/t 23.8 kWh/t 1482 t/h
Difference 1.6 kWh/t 1.9 kWh/t 3.9 kWh/t -188 t/h
Difference 15% 14% 16% -13%

Show details of benchmarking

Benchmarking: Bond/Barratt - Cadia

Dunne, R., Morrell, S., Lane, G., Valery, W. and Hart, S., Design of the 40 foot diameter SAG mill installed at the Cadia gold copper mine. Proceedings of SAG 2001, pages I-43 to I-58.

Lane, G., Foggiatto, B. and Bueno, M, Power-based comminution calculations using Ausgrind. Proceedings of Procemin 2013, Chapter 2, paper 2.

  • Survey conducted shortly after start-up

Result for default Optimized Bond/Barratt SABC model conditions:

Esag Epeb Ebm Etotal t/h
Predicted 8.6 0.3 8.5 17.4 2000
Survey 8.6 - 8 16.6 2065
Difference 0 0.3 0.5 0.8 -65
Difference 0% - 6% 5% -3%

Show details of benchmarking

Benchmarking: Bond/Barratt SABC Circuit Specific Energy Consumption - Copper Mountain

  • Morrison, R., Current Plant Conditions at Copper Mountain. Presentation to the BC/Yukon Branch Canadian Mineral Processors, November 29, 2012; Vancouver, Canada.

Result for default Optimized Bond/Barratt model conditions:

Tonnage
Model 1455 t/h
Measured 1600 t/h
Difference 145 t/h
Difference 9.5%


Show details of benchmarking

Benchmarking: Bond/Barratt SAG Mill Specific Energy Consumption - Detour Lake

  • J. Torrealba-Vargas, J.-F. Dupont, J. McMullen, A. Allaire and R. Welyhorsky, The successful development of the detour lake grinding circuit: from testwork to production. Proceedings of the SAG 2015 Conference, September 2015, Vancouver, Canada, Paper 38.

The mill is in the final stages of ramp-up, and has not reached its ultimate capacity. If we use the April/May 2015 values from Figure 5, the results look like:

  • Etotal : model 7% low
  • t/h : model 13% high

The throughput is likely to continue to increase as the ramp-up continues, so the difference between the model and the actual plant is likely to reduce.

Show details of benchmarking

Benchmarking: Bond/Barratt SAG Mill Specific Energy Consumption - Esperanza

  • Villanueva, F. and Soto, L., SEC and the impact on a mills selection for DMC project. Proceedings of the XXVII International Mineral Processing Congress, October 2014, Santiago, Chile. C14-23.

Paper describes modelling of two expansion cases (Esperanza Sur and Encuentro). Some operating data for the current Esperanza pit & plant are provided as they were used to tune the comminution models used for the expansion cases.

Average ore
Measured SAG specific energy consumption, kWh/t 5.5
Predicted SAG specific energy consumption, kWh/t 5.9
Difference, kWh/t 0.4
Difference, % model predicts 7% high

Show details of benchmarking

Benchmarking: Bond/Barratt SABC Circuit Specific Energy Consumption - Fort Knox

  • Magnuson, R.; Hallow, J.; Mosher, J.; Major, K., The Fort Knox Mill: Design, Commissioning and Operation. Proceedings of the SAG 2001 Conference, Vancouver, Canada.

Optimized Bond/Barratt SABC circuit (10% Essbm calibration factor).

Result for default model conditions:

Etotal WiO Tonnage
Model 11.43 15.90 kWh/t 1,607 t/h
Measured 10.50 14.61 kWh/t 1,733 t/h
Difference 0.93 1.29 kWh/t 126 t/h
Difference 8.9% 8.8% 7.3%

Model predicts 8.9% harder than survey resulting in predicted throughput 7.3% lower than survey.

Show details of benchmarking

Benchmarking: Bond/Barratt SABC Circuit Specific Energy Consumption - Kanowna Belle

Lunt, D.J., Thompson, A. and Ritchie, I. The Design and Operation of the Kanowna Belle Milling Circuit, SAG 1996, Pages 81-96.

Survey Optimized
Model
Difference
ESAG 12.55 kWh/t 13.27 kWh/t +5.7%
Eball 9.70 kWh/t 10.24 kWh/t +5.6%
Epeb 0.99 kWh/t 1.04 kWh/t +5.2%
Etotal 23.24 kWh/t 24.55 kWh/t +5.6%

Two possible circuit models were tested, and the Optimized Bond/Barratt SABC model better matches the survey than the Raw Bond/Barratt model.

Show details of benchmarking

Benchmarking: Bond/Barratt SABC Circuit Specific Energy Consumption - Meadowbank

  • Muteb, P. & Allaire, J., Meadowbank Mine Process Plant Throughput Increase, Proceedings of the Canadian Mineral Processors Annual General Meeting, Ottawa, Canada, January 2013.

Paper describes a "sick" SAG mill and the changes made to "bring it to health". The "healthy" mill conditions benchmark as follows:

  • Actual SAG/ball motor powers (at shell): 3,168 kW / 4,105 kW
  • Actual daily average throughput: 500 tonnes/hour
  • Predicted SAG/ball motor powers (at shell): 3,096 kW / 4,182 kW
  • Predicted nominal throughput: 500 tonnes/hour (0% difference)
SAG Ball Mill total
Measured specific energy consumption, kWh/t 6.34 8.21 14.55
Predicted specific energy consumption, kWh/t 6.19 8.36 14.55
Difference, kWh/t -0.15 0.15 0.00
Difference, % -2.3% 1.8% 0.0%

Show details of benchmarking

Benchmarking: Amelunxen SGI SABC Circuit Specific Energy Consumption - Macraes

Barns, K., Lane, G., Osten, K. & Scagliotta, N., Benchmarking Energy Efficiency - A Case Study at Macraes Gold Mine, Proceedings of the AusIMM MetPlant conference, Perth, Australia, September 2004.

Survey 5 Survey 4 Survey 3 Survey 2 Survey 1 Overall
Average
SAG specific power 7.1% 7.6% 23.4% 5.0% 9.4% 10.5%
ball mill specific power 7.1% 7.7% 16.6% 4.9% 11.4% 9.6%
total specific power 7.1% 7.7% 19.0% 5.0% 10.8% 9.9%
CFball -17.5% 16.9% 0.5% 10.6% 8.3% 3.8%

The overall specific energy consumption predictions of the model are conservative by about 10%. The CFball predictions are within 4% overall, but can be wildly different on any particular sample. Circuit feed sizes were varied during the surveys, ranging between 51 and 107 mm; the SGI equation doesn't have a explicit F80 term, so feed sizes may be confusing the method.

Show details of benchmarking

Benchmarking: Bond/Barratt SABC Circuit Specific Energy Consumption - Macraes

Barns, K., Lane, G., Osten, K. & Scagliotta, N., Benchmarking Energy Efficiency - A Case Study at Macraes Gold Mine, Proceedings of the AusIMM MetPlant conference, Perth, Australia, September 2004.

Difference between model results and plant surveys:

Survey 5 Survey 4 Survey 3 Survey 2 Survey 1 Overall
Average
SAG specific power -5.3% -5.0% 6.3% 0.5% 2.2% -0.2%
ball mill specific power -6.3% -4.7% 3.6% 1.9% 3.2% -0.5%
total specific power -6.8% -3.8% 5.4% 1.4% 2.9% -0.2%

Show details of benchmarking

Benchmarking: Bond/Barratt ABC Circuit Specific Energy Consumption - Santa Rita

Latchireddi, S. & Faria, E., Achievement of High Energy Efficiency in Grinding Mills at Santa Rita, Proceedings of the Canadian Mineral Processors Annual General Meeting, Ottawa, Canada, January 2013.

Faria, E. & Latchireddi, S., Commissioning and Operation of Milling Circuit at Santa Rita Nickel Operation, Paper #137: Proceedings of the International Autogenous Grinding, Semiautogenous Grinding and High Pressure Grinding Roll Technology Conference, Vancouver, Canada, September 2011.

FAG BM Pebble
Crusher
total
Measured specific energy consumption, kWh/t 9.55 7.28 0.34 17.18
Predicted specific energy consumption, kWh/t 9.78 8.33 0.39 18.50
Difference, kWh/t 0.23 1.05 0.05 1.32
Difference, % 2.4% 14.4% 14.7% 7.7%

Show details of benchmarking

Benchmarking: Bond/Barratt SAB Circuit Specific Energy Consumption - Selbaie

Duval, L. and Wood, K., Testing, Design and Operation of SAG Circuit at Les Mines Selbaie, Proceedings of the SAG 1989 Conference, Vancouver, Canada, September 1989.

Wood, K. and Duval, L., Mill Expansion at Les Mines Selbaie, Proceedings of the 25th Anniversary Issue of the Canadian Mineral Processors, Ottawa, Canada (Paper № 8), January 1987.

  • SAB circuit
  • SAG feed F80 = 117 mm
  • cyclone overflow, P80 = 45 µm
SAG BM total
Predicted specific energy consumption, kWh/t 11.99 12.37 24.37
Predicted operating work index, metric 20.3 14.2 16.7
Measured operating work index, metric 20.0 13.8 16.0
Difference, metric Wi units 0.3 0.4 0.6
Difference, % 2% 3% 4%


Show details of benchmarking

Benchmarking: Bond/Rowland SSBM Circuit Specific Energy Consumption - Boddington

The Bond/Rowland SSBM model was fit to the observed operation of the Boddington HPGR circuit. The fitting parameters are:

  • Essbm calibration factor: (-0.13)
  • Mechanical efficiency of HPGR crushers: 0.28.

Because the model is specifically fit to the Boddington data, it doesn't make any meaningful throughput predictions, but the following predictions are available:

  • Ball mill operating work index reduction versus laboratory: 5% (microcracking/phantom cyclone effect)
  • Secondary crusher WiO is 18.1 kWh/tonne (versus laboratory determination 27.7 kWh/t).

Show details of benchmarking

Benchmarking: Bond/Rowland SSBM Circuit Specific Energy Consumption - Tropicana

The Bond/Rowland SSBM model was fit to the observed operation of the Tropicana HPGR circuit. The fitting parameters are:

  • Essbm calibration factor: (0%)
  • Mechanical efficiency of HPGR crushers: 0.44.

Show details of benchmarking

Benchmarking: Morrell Mih model Circuit Specific Energy Consumption - Tropicana

The Morrell Mi model (SMC test & recalibrated ball mill work index) was compared to the observed operation of the Tropicana HPGR circuit:

Model Prediction Survey Actual Difference
EsecCr 0.52 kWh/t 0.40 kWh/t model 30% high
Ehpgr 2.83 kWh/t 2.60 kWh/t model 9% high
Eball 18.36 kWh/t 16.77 kWh/t model 9% high
Etotal 21.70 kWh/t 19.77 kWh/t model 10% high

The Morrell model is about 10% conservative versus the survey results.

The throughput determined by the ball mill treatment rate is 710 t/h, versus observed 734 t/h (model is 3% conservative).

Show details of benchmarking

Benchmarking: Bond/Barratt Single Stage SAG model Circuit Specific Energy Consumption - Yanacocha

Two surveys were published, the first survey was noted that "the circuit was not operating efficiently", so the model predictions are expected to be optimistic.

Survey Actual Model Prediction Difference Comment
Survey 1 EASAG 19.8 kWh/t 16.4 kWh/t model 20% low Ignore survey, mill operating poorly
Survey 2 EASAG 18.0 kWh/t 16.3 kWh/t model 10% low Survey probably OK

The first survey has significantly higher energy consumption than the model predicts. The author of the reference paper says that the mill was not operating well, so it is reasonable to ignore this survey and not use it as a valid "benchmark" as we are only interested in benchmarking against circuits that are operating "well".

The second survey is operating better, and can be assumed valid basis for benchmarking.

Show details of benchmarking

Benchmarking: Morrell Mi Single Stage SAG model Circuit Specific Energy Consumption - Yanacocha

The same two surveys as the Bond/Barratt model (above) give the following:

Survey Actual Model Prediction Difference Comment
Survey 1 EASAG 19.8 kWh/t 12.7 kWh/t model 56% low Ignore survey, mill operating poorly
Survey 2 EASAG 18.0 kWh/t 12.5 kWh/t model 43% low Significant difference

Both these predictions are significantly different from the surveys. Either the circuit is performing much worse than the Bond/Barratt model predicts or else there is something in Yanacocha that is confusing the Mi method.

Show details of benchmarking

Benchmarking: Private surveys

Private surveys that do not include details, but the difference between plant performance and model predictions are provided below:

  • Project 0082, using Optimized Bond-Barratt model.
  1. SAB survey: Etotal: actual = 6.72 kWh/t, predicted = 6.78 kWh/t, difference 0.9%
  2. ABC survey: Etotal: actual = 7.75 kWh/t, predicted = 8.14 kWh/t, difference 4.8%