Model:Morrell Mi SMC SAG

From SAGMILLING.COM
Revision as of 21:46, 25 April 2015 by Alex Doll (talk | contribs) (CFsag calibration factor)
Jump to: navigation, search

Morrell SMC SAG & ball mill Model

This is a SAG or AG mill plus ball mill model that estimates the specific energy consumption (ESAG) using the equations of Morrell (2004).


Testwork Required

  • The SMC™ test, stored in the "DWT" testwork table (Drop Weight Test).
  • Bond ball mill work index. The method requires all the elements of the ball mill work index test to be filled in:
    • Ball mill Wi test closing screen size, umclosing, µm
    • Ball mill Wi test product size, P80, µm
    • Ball mill Wi test feed size, F80, µm
    • Ball mill Wi grams per revolution at test conclusion, gpr

Formulae

The method is superficially similar to Bond (among other models), but with a variable exponent on size defined by: f(x) = - 0.295 - \frac{x}{10^6}

Where x is the particle 80% passing size in µm.

E_{total} = 4 \times Mia \left( 750^{f(750)} - F_{80}^{f(F_{80})} \right) \times CFsag + 4 \times Mib \left( P_{80}^{f(P_{80})} - 750^{f(750)} \right)
Morrell, 2004

E_{SAG} = 4 \times Mia \left( P_{80}^{f(P_{80})} - F_{80}^{f(F_{80})} \right) \times CFsag
Morrell, 2004

E_{ball} = E_{total} - E_{SAG} Morrell, 2004

CFsag calibration factor

The CFsag factor is used to reflect the effect of pebble crushing on the overall circuit performance. This value is automatically selected if you leave this field blank in the model configuration settings.

  • Base value, SAB circuit (no pebble crushing, ~6 inch SAG feed), CFsag = 1.00
  • Pebble crushing, SABC circuit, CFsag = 0.95

Transfer size

Morrell specifically discourages use of transfer size in calculations such as those in SAGMILLING.COM for a variety of reasons (see discussion in Morrell, 2011). Unfortunately, the alternative method proposed by Morrell is a complex equation that requires pre-selected mill sizes and a series of unpublished calibration factors. This alternative method is not practical for the calculations in SAGMILLING.COM, so a transfer size approach is used instead.

The modelled transfer sizes are probably "Bond-compatible" and not similar to what would be measured directly in a plant survey. Plant survey results would need to be subjected to a phantom cyclone calculation before they are comparable to the model predictions.