Difference between revisions of "Testwork: Aggregating samples"

From SAGMILLING.COM
Jump to: navigation, search
(Created page with "===Queries Table=== thumb|Screenshot showing portion of a large query table The list of samples that run through a circuit model is shown in the ...")
 
m (Queries Table)
Line 1: Line 1:
 
===Queries Table===
 
===Queries Table===
[[file:Testwork-queries.png|thumb|Screenshot showing portion of a large query table]]
+
[[file:Testwork-queries.png|thumb|Screenshot showing portion of a large queries table]]
 
The list of samples that run through a circuit model is shown in the "Queries" table. This is the list of samples that contain all of the necessary test results required to satisfy a particular model. For example, the "queries" table for a Bond/Barratt model will show only those samples that have a [[Testwork: Crushing work index|crushing work index]] (WiC), [[Testwork: Bond rod mill work index|Bond rod mill work index]] (WiRM) and a [[Testwork: Bond ball mill work index|Bond ball mill work index]] (WiBM). Any sample that lacks any of these three values can not be run in the model and will not appear in the listing.
 
The list of samples that run through a circuit model is shown in the "Queries" table. This is the list of samples that contain all of the necessary test results required to satisfy a particular model. For example, the "queries" table for a Bond/Barratt model will show only those samples that have a [[Testwork: Crushing work index|crushing work index]] (WiC), [[Testwork: Bond rod mill work index|Bond rod mill work index]] (WiRM) and a [[Testwork: Bond ball mill work index|Bond ball mill work index]] (WiBM). Any sample that lacks any of these three values can not be run in the model and will not appear in the listing.
   

Revision as of 18:36, 3 January 2013

Queries Table

File:Testwork-queries.png
Screenshot showing portion of a large queries table

The list of samples that run through a circuit model is shown in the "Queries" table. This is the list of samples that contain all of the necessary test results required to satisfy a particular model. For example, the "queries" table for a Bond/Barratt model will show only those samples that have a crushing work index (WiC), Bond rod mill work index (WiRM) and a Bond ball mill work index (WiBM). Any sample that lacks any of these three values can not be run in the model and will not appear in the listing.

The "queries" table can not be directly manipulated. The list is generated automatically by combining individual test results by matching the sample name and program fields.